Digital Indicator, Peak Hold ID-C 12,7mm, 0,001mm, Lug Back Plate 543-300-10 Mitutoyo

  • Rating:
    0 reviews
  • Manufacturer:
  • Model:
    543-300-10
  • SKU:
    ID-C112AX2
  • Available:
    In stock
  • Model:
    ID-C112AX2
  • ABS / INC (INC ZERO):
    Yes
  • ABS/INC switchable:
    Yes
  • Alarm:
    Low voltage, ABS composition error, overflow error, setting error
  • Analog bar resolution switchable:
    Yes
  • Battery life:
    Standard mode: approx. 1 year fast mode: approx. 4.5 month
  • Calculation function (with formula):
    Yes
  • Contact point:
    Carbide ball, thread: M2.5x0.45
  • Counting direction switchable:
    Yes
  • DATA/HOLD:
    Yes
  • Delivered:
    Including CR2032 battery, certificate of inspection
  • Digimatic data output:
    Yes
  • Digital Scale:
    Electrostatic capacitance type absolute linear encoder
  • Digital step:
    0.001 mm/0.01 mm
  • Digital step switchable:
    Yes
  • Digital/Analog:
    Digital
  • Display:
    LCD, character height 8 mm, 330° rotatable
  • Fast measurement mode:
    Yes
  • Function lock:
    Yes
  • GO/±NG judgement:
    Yes
  • H MPE (Hysteresis):
    0.002 mm
  • Inch-Metric:
    Metric
  • Inch/Metric switchable:
    No
  • Low voltage alarm:
    Yes
  • Mass:
    180
  • Max. Permissible Error E MPE (Total Range):
    0.003 mm
  • Max. response speed:
    Unlimited
  • MAX/MIN/RANGE:
    Yes
  • Measurement frequency (MAX/MIN/RANGE):
    Standard mode: 10 times/s fast mode: 50 times/s (plunger speed max. 50 µm/s for peak measurement)
  • Measuring force MPL:
    ≤1.5 N
  • ON/OFF:
    Yes
  • Power supply:
    1 battery CR2032
  • PRESET 3x:
    Yes
  • Protection:
    IP42
  • R MPE (Repeatability):
    0.002 mm
  • Range:
    12.7
  • Stem ∅:
    8 mm
  • Type:
    EN ISO Standard
511.00€
In stock

Description

This indicator is the MAX/MIN/RANGE value holding function model

It offers the following benefits:

  • The MAX/MIN/RANGE (run-out value) can be measured.
  • A fast measurement frequency mode(detection cycle 20 ms or 50 times/s) is selectable to measure in the peak detection mode (MAX/MIN/RANGE) more reliably.
  • Easy indicator setup via a setup menu.
  • Analogue bar graph in the display (12 different scales switchable).
  • GO/±NG tolerance judgement function.
  • This indicator enables the use of a calculation function for the measured value Ax.
  • Coefficient A is freely definable and x = displacement of the plunger.
  • A USB interface box can be used to set up the indicator from PC via dedicated software.

Reviews (0)

Write a review